Cooling Distribution Units

At Hydraquip, we help you meet growing data center cooling demands with HydraCOOL by SIT. In partnership with our sister company, we offer a 1 MW CDU and the components that connect it to your cooling system.

CDU solutions that work behind the scene

FLUID CONVEYANCE
CONNECTIONS

Flexible hose assemblies and couplings connecting CDU systems.

PUMP
SYSTEMS

Variable speed pumps designed to maintain stable coolant circulation.

FILTRATION
SYSTEMS

Bag filtration and contamination monitoring systems protecting cooling loops.

PRESSURE AND
TEMPERATURE MONITORING

Pressure and temperature sensors provide real-time operating data to support coolant monitoring, system diagnostics, and reliable CDU performance.

CUSTOM TURNKEY
PACKAGES

Custom turnkey liquid cooling skids built through our sister company, Supreme Integrated Technology.

Components Engineered For Rack-Level Cooling

QUICK DISCONNECT COUPLINGS

Danfoss FD83 and UQD couplings create secure, service-friendly liquid cooling connections. Low-spill designs help reduce coolant loss and air entry during equipment maintenance.

PEROXIDE-CURED EPDM HOSE ASSEMBLIES

EPDM-P cooling hose assemblies provide flexible fluid conveyance in tight rack environments. They support reliable routing between CDUs, manifolds, heat exchangers, and IT equipment.

TEMPERATURE MONITORING SYSTEMS

Resistance temperature detectors (RTDs) and thermocouples measure coolant temperature near critical equipment, providing operating data for system monitoring, diagnostics, and control.

INSTRUMENTATION MANIFOLDS

Instrumentation manifolds create organized measurement and service points within rack-level cooling loops. They support accessible pressure and temperature monitoring for diagnostics and maintenance.

RACK-LEVEL HEAT EXCHANGERS

Air-to-liquid and rear-door heat exchangers remove heat near server racks. They support efficient thermal management in liquid-cooled and hybrid high-density data center environments.

COOLING DISTRIBUTION UNITS

Precise cooling. Reliable performance.

What does a cooling distribution unit do? A cooling distribution unit, more commonly called a coolant distribution unit or CDU, manages heat transfer between the facility water system and the technology cooling system serving liquid-cooled IT equipment. It circulates and conditions coolant while helping regulate temperature, pressure, and flow for consistent cooling performance.

HydraCOOL supports CDU design and integration with fluid-conveyance connections, variable-speed pumps, heat exchangers, filtration, valves, sensors, instrumentation, drives, and controls. Through our sister company, Supreme Integrated Technology, we can also support custom turnkey liquid cooling skids engineered around cooling demand, available space, control requirements, redundancy, service access, and system integration.

Simplified CDU Design. Scalable Redundancy.

HydraCOOL by SIT uses a single-circuit CDU design that simplifies the system by shifting redundancy from individual components to the CDU level. This approach reduces component complexity and is designed to improve operating efficiency while lowering cooling-related energy consumption.

To maintain reliability, each CDU includes redundant critical sensors and controls. For data center applications requiring high availability, Hydraquip and Supreme Integrated Technology recommend an N+2 CDU redundancy configuration, providing two additional CDUs beyond the capacity required to meet the cooling load.

A cooling distribution unit (CDU) manages coolant within a data center liquid cooling system. It typically transfers heat between the facility water system and the technology cooling system while controlling the temperature, pressure, and flow of coolant delivered to racks.

A data center CDU typically includes pumps, heat exchangers, filters, valves, sensors, instrumentation, and controls. Depending on system requirements, it may also incorporate variable-frequency drives, expansion equipment, hoses, and quick-disconnect couplings. Boston by Danfoss hose solutions and Danfoss Hansen® couplings can support fluid connection and conveyance requirements.

A CDU supplies conditioned coolant through piping, flexible hose assemblies, and rack manifolds. In direct-to-chip applications, manifolds distribute coolant to cold plates mounted directly to server processors. Aeroquip® by Danfoss DataCryo DC394 Hose supports coolant conveyance in data center liquid cooling infrastructure, particularly in source-line applications. Heated coolant returns to the CDU for heat transfer to the facility water system.

Rack-level liquid cooling systems commonly use flexible hose assemblies, quick-disconnect couplings, rack manifolds, temperature and pressure sensors, instrumentation manifolds, and heat exchangers. Danfoss Hansen® Universal Quick Disconnect (UQD) connections provide a solution for serviceable fluid connections in liquid cooling applications. These components deliver coolant, monitor operating conditions, and create serviceable connections.

Quick-disconnect couplings provide removable connections between cooling equipment, manifolds, and servers. Low-spill designs help minimize coolant loss during maintenance. Danfoss Hansen® UQD couplings feature push-to-connect operation and double-shutoff valves, while FD83 couplings offer full-flow performance and a dual-interlock design.

Yes. HydraCOOL supports CDU component selection and integration. Through Supreme Integrated Technology, Hydraquip can also support custom turnkey liquid cooling skids that integrate pumps, heat exchangers, filtration, valves, instrumentation, drives, controls, hoses, and couplings.

Yes. HydraCOOL provides hoses, quick-disconnect couplings, manifolds, monitoring components, and related fluid-conveyance solutions that support coolant delivery in direct-to-chip data center cooling systems.

Cooling distribution units support AI and high-density data centers by delivering controlled coolant flow to liquid-cooled server racks. By regulating coolant temperature, pressure, and flow, CDUs help remove high heat loads, maintain stable operating conditions, and support reliable system performance as computing density increases.

HydraCOOL uses a single-circuit design with redundant critical sensors and controls. Rather than duplicating major components within each CDU, Hydraquip and Supreme Integrated Technology recommend N+2 redundancy at the CDU level, providing two additional units beyond the capacity required to meet the cooling demand. This approach simplifies individual CDUs while supporting system-level reliability.

Expansive Regional Footprint

Based in Houston, Texas, Hydraquip operates under its parent company, Employee Owned Holdings Inc. (EOH), and has expanded its footprint through strategic acquisitions and new locations across Texas, Louisiana, Oklahoma, Colorado, Arizona, Mississippi, Arkansas, Tennessee and New Mexico. This growth includes the addition of companies such as Flint Hydraulics and the creation of specialized divisions like Flint, HydraCool, and Hydraquip Electric Systems (HES).

  • 75 Years Experience
  • 9 States Served
  • 150+ Employees
our location
contact us